Thursday, 28 January 2016

Swab And Surge Pressures

Swab And Surge Pressures

Both swab and surge pressures are caused by moving the drillstring axially, and can be calculated using a method similar for calculating annular pressure losses. The greatest difficulty is determining the fluid flow velocity in the annulus when the pipe is opened-ended, because the
distribution of flow between the drillstring and annulus cannot be determined by a simple method.
Two approaches have been proposed.

The first assumes that fluid levels in the annulus and drillstring remain equal at all times. Annular fluid velocity then becomes:


where: Va = Average velocity (ft/min)
Vp = Drillstring velocity (ft/min)
D = Borehole Diameter (inches)
d = Drillstring Outside Diameter (inches)
di = Drillstring Inside Diameter (inches)

The minus sign is in the equation because the drillstring velocity is in the opposite direction to the fluid velocity.

This average velocity equation remains valid even when hole geometry changes. This method is easy to apply and is in widespread use in the oilfield. Its basic premise, that fluid levels in the drillstring and annulus
remain equal, is rarely justified. Because of the greater restrictions to flow, caused by the bit nozzles and pipe bore, actual flow in the annulus will nearly always exceed that calculated by this method. Calculated swab and surge pressures are therefore usually too low.


An alternative procedure considers the drillstring and the annulus as a “UTube”, as shown in the following figure.
 It is clear that the sum of hydrostatic and frictional pressures in the pipe bore and through the bit should equal the sum of hydrostatic and frictional pressures in the annulus. Both sums represent the pressure prevailing immediately below the bit.
There is only one flow distribution that will fulfill this criterion, and it can
be found by trial and error through the use of the pressure loss equations.

Figure 1-3: Equal Level Displacement

When tripping out of the hole, it may be assumed that both drillstring and annulus are kept full of fluid. The required distribution of flow is that which gives equal frictional losses in the pipe bore and annulus. When tripping into the hole, the fluid level inside the drillstring can drop well below that in the annulus, if small bit nozzles are present. This effect is usually seen as a pit volume being higher than expected, string weight lower than expected, and a considerable volume being pumped before standpipe pressure builds up while breaking circulation.

When the fluid level in the drillstring is below that of the annulus, a greater hydrostatic pressure will exist in the annulus, and fluid will tend to flow from the annulus up the drillstring. In this case, calculating flow distribution by equating frictional losses gives a calculated annular flow and surge pressure slightly higher than actually exists. Because this error is small and conservative, and because at present there is no reliable way of measuring the fluid level within the pipe, the practice of calculating flow distribution by equating internal and external pressure losses is generally accepted.

If the pipe is closed, or contains a float sub, it is easy to calculate flow in the annulus, because all of the fluid displaced by the drillstring passes up the annulus.

Calculating the pressure drop in the annulus is complicated by the motion of the inner wall of the drillstring. This motion is in the opposite direction to the displaced fluid, so the pressure drop will be greater than that for the same flowrate in a stationary annulus . Equations describing the system can be formulated, but solutions are usually too complicated for wellsite use.
Figure
 

Bit Hydraulics And Optimization - Diamond Bit Flow Patterns

Diamond Bit Flow Patterns

There are two main flow patterns in diamond bits:

1. Cross Pad Flow System (feeder/collector system)

a) the fluid travels along the high pressure “primary fluid courses” (those which connect to the crowfoot), to a point where “low pressure collectors” draw the fluid across the diamond pad
b) this ensures that the diamonds towards the outside diameter are cleaned and cooled
c) The HSI should be between 1.5 and 2.5.

2. Radial Flow System

a) provides a “high pressure primary fluid course” for each diamond row
b) permits fluid to travel in front of, and behind each diamond pad to facilitate cuttings removal and cooling
c) maintains uniform horizontal fluid velocity by tapering fluid course depth as they approach the outside diameter
d) The HSI should be between 2.0 to 3.0.




Drill String Sticking Prevention





Stuck pipe
During drilling operations, a pipe is considered stuck if it cannot be freed from the hole without damaging the pipe, and without exceeding the drilling rig’s maximum allowed hook load. Pipe sticking can be classified under two categories: differential pressure pipe sticking and mechanical pipe sticking.
Mechanical causes for stuck pipe include:
Keyseating
Packoff from poor hole-cleaning
Shale swelling
Wellbore collapse
Plastic-flowing formation (i.e., salt)
Bridging
Preventing stuck pipe can require close monitoring of early warning signs, such as:
Increases in torque and drag
Excessive cuttings loading
Tight spots while tripping
Loss of circulation while drilling .

Bit Hydraulics And Optimization - Diamond Bit Hydraulics

Diamond Bit Hydraulics

The horizontal fluid velocity is the key element in diamond bit life and bit performance. It can be determined using:
The fluid courses assist this by directing the drilling fluid across the bit to cool the diamonds and to remove the cuttings.

 The diamond bit “Total Flow Area” consists of two components:

1. Fluid Course Area - is the area of all fluid courses on the bit. They are cast into the bit body.
2. Diamond Exposure Area - is the area between the bit face and formation, produced by the diamond exposure.

The desired TFA is calculated and designed into the bit by varying the diamond exposure, and the width and depth of the fluid courses. Another phenomenon which occurs with natural diamond bits is called hydraulic pump-off. The hydrodynamic pressure of the mud at the bit acts over the bit face area (between the cutting face of the bit and the formation) and tends to lift the bit off the bottom of the hole. For example, the pumpoff force on a 8-1/2 inch radial flow diamond bit (having a pressure drop of 900 psi) would be approximately 8600 pounds. It will require at least this much bit weight to keep the face of the bit in contact with the bottom of the hole.

Bit Hydraulics And Optimization - PDC Bit Hydraulics

PDC Bit Hydraulics

Since PDC bits are formation specific (best used in plastic formations), the formation characteristics will determine the hydraulic energy required. The drilling fluid will dictate the HSI, for water-based drilling fluids it will be between 2.5 and 4.5, while for oil-based drilling fluids it will be between 1.5 and 3.0.

The HSI, calculated at the jet nozzle orifices, will have several characteristics which will directly affect hydraulic energy:

1. the fluid velocity decreases rapidly once it leaves the nozzles
2. high vertical velocity and low horizontal velocities are achieved across the bit face
3. for higher volumes of fluid pumped, horizontal velocities will increase, but not necessarily HSI

The increased horizontal velocities provide better cuttings removal, better cooling, and possibly better drill rates.

Nozzle velocity is calculated in the same manner as with rollercone bits.

Bit Hydraulics And Optimization-Fixed Cutter Bit Hydraulics

Fixed Cutter Bit Hydraulics
The hydraulics for fixed cutter bits is based on the drilling fluids ability to remove cuttings beneath the cutters and to cool the bit. Fluid volume is critical to PDC bit performance. Fluid volume and fluid velocity is critical to diamond bit performance.

The major components of fixed cutter bit hydraulics are:

1. flow rate - Q (gal/min) and V (ft/min)
2. drilling fluid characteristics - MD (lb/gal), YP (lbs/100ft2) and PV (cps)
3. pressure loss - across the bit face (diamond bit) or through the jet nozzles (PDC bit)
4. the Total Flow Area (TFA) - instead of nozzle sizes

A very important parameter in fixed cutter bits is “Hydraulic Power Per Square Inch” or HSI. It is calculated using Hhp (hydraulic horsepower):

where: Hhp = Hydraulic Horsepower
A = Bit Area (square inches)*
* If the area of the bit is not given, it can be calculated using:

where: d = bit diameter (inches)
The hydraulic horsepower equation is the same (Pb x Q/1714), however in fixed cutter bits, resistance to fluid flow is created by the diamonds, nozzles, flow area restrictions, cuttings and the uneven hole pattern. Pressure losses at the bit are calculated using:

Bit Hydraulics And Optimization - Hydraulic Impact Force

Hydraulic Impact Force
Hydraulic (Jet) Impact Force is based on the theory that cuttings are best removed from beneath the bit when the force of the fluid leaving the jet nozzles and striking the bottom of the hole is the greatest. Impact Force is determined by:




where: MD = Mud Density (lb/gal)
Q = Flow Rate (gal/min)
Vn = Nozzle Velocity (ft/sec)
As can be seen, Impact Force depends on maximizing flow rate and nozzle velocity rather than pressure. Therefore, higher flow rates are required. The emphasis is on a large volume of fluid impacting with moderate force, rather than a small volume impacting at a high pressure.
This condition is optimized when circulating rates and bit nozzle sizes are chosen which will cause 48% of the pump pressure to be used to force fluid through the jet nozzles.